SmartOnline 200-240V 3kVA 2.4kW On-Line
Double-Conversion UPS, Extended Run, SNMP,
Webcard, 3U Rack/Tower, DB9 Serial
MODEL NUMBER: SU3000RTXL3UHV
Description
3000VA / 3kVA on-line, double-conversion UPS system for critical server, network and telecommunications
equipment. 3U rackmount form factor with an installed depth of 20 inches (50.8cm). Expandable battery runtime
with optional external battery packs BP72V15-2U (limit 1), BP72V28RT-3U (multi-pack compatible) and
BP72V18-2US (multi-pack compatible). Full time sine wave 200/208/220/240V AC output with +/-2% voltage
regulation. Online, double-conversion Uninterruptible Power Supply (UPS) actively converts raw incoming AC
power to DC, then re-converts output back to completely regulated, filtered AC output. Operates continuously
without using battery power during brownouts to 130V and overvoltages to 275V. NEMA L6-20P input plug.
NEMA 6-15/20R & L6-20R output receptacles. Network-grade AC surge and noise suppression. Zero transfer
time between AC and battery operation. Network management interfaces support simultaneous communications
via DB9 serial port and SNMPWEBCARD slot. Built-in DB9 port offers both enhanced RS-232 enabled
monitoring data, plus contact closure monitoring ability. Supports simultaneous detailed monitoring of equipment load levels, self-test data and mains power
conditions via all network interfaces. Includes PowerAlert monitoring software and complete cabling. Integrated two bank PDU switching supports load
shedding and remote-reboot of connected equipment. Multi-stage metered current monitoring and battery charge status LEDs. Mains power and voltage
regulation LEDs. Audible Alarm. Self-test. Fault-tolerant auto-bypass mode. 4 post rackmount accessories included; 2-9USTAND tower kit and
2POSTRMKITWM 2-post rackmount accessories available. Field replaceable, hot swappable internal batteries and external battery packs. Attractive all-black
UPS design. $250,000 Ultimate Lifetime Insurance (U.S., Canada, and Puerto Rico only).
Features
True on-line, double conversion UPS provides pure, sine wave AC output at all times
Maintains continuous operation through blackouts, voltage fluctuations and surges with zero transfer time
Removes harmonic distortion, electrical impulses, frequency variations and other hard to solve power problems
Accepts input voltages between 160 and 275 (130 to 275 at loads under 70%), regulating output to selectable 200/208/220/240V +/-2%
3000VA/2400 watt power capacity with 8 total outlets (6 NEMA6-15/20R & 2 NEMAL6-20R)
Standard internal battery set provides 14 minutes runtime at half load
Highlights
3000VA / 3kVA / 2400 watt
on-line double-conversion 3U
rack/tower UPS
208/240V +/-2% output at
50/60Hz
Expandable runtime,
Hot-swappable battery modules
RS232 port; support for
SNMP/WEB card options
Front panel status LEDs with
detailed load and battery metering
NEMA L6-20P input; 6-15/20R &
L6-20R outlets
Applications
Distributed Server Rooms
Network Closets
Small Business Networks
Voice over IP (VoIP) Phone
Systems
Package Includes
SU3000RTXL3UHV Rack-Tower
UPS System
PowerAlert Software and cabling
Mounting hardware for 4 post
rackmount enclosures
Warranty information
Instruction manual
1 / 6
Vue de la page 0
1 2 3 4 5 6

Résumé du contenu

Page 1 - MODEL NUMBER: SU3000RTXL3UHV

SmartOnline 200-240V 3kVA 2.4kW On-LineDouble-Conversion UPS, Extended Run, SNMP,Webcard, 3U Rack/Tower, DB9 SerialMODEL NUMBER: SU3000RTXL3UHV Desc

Page 2 - Specifications

Expandable runtime with external battery packs BP72V15-2U (limit 1), BP72V28RT-3U (multi-pack compatible) and BP72V18-2US (multi-packcompatible)Innova

Page 3

Load Management Receptacles Two switchable 6-15/20R load banks (bank 1 - two outlets, bank 2 - four outlets)Output AC Waveform (AC Mode) Pure Sine wav

Page 4

Audible Alarm Audible alarm indicates UPS startup, power-failure, low-battery, overload, UPS fault and remote shutdown conditionsFront Panel LCD NoLED

Page 5

UPS Shipping Dimensions (hwd / in.) 13.3 x 23.8 x 25.7UPS Shipping Dimensions (hwd /cm)33.8 x 60.5 x 65.3Shipping Weight (lbs.) 90.3Shipping Weight (k

Page 6

WARRANTYProduct Warranty Period (Worldwide) 2-year limited warrantyConnected Equipment Insurance(U.S., Canada & Puerto Rico)$250,000 Ultimate Life