Chapter 6. Menu Options
IPMI Settings
Figure 6-33 shows the B050-000 IPMI settings panel. Its options will be explained
below.
IPMI disabled
Disables IPMI on the B050-000. This means that Status via IPMI and Event Log
via IPMI are not available and the power on/off and reset functions do not use
IPMI rather than the ATX and the reset cable connected from the B050-000 to the
motherboard.
IPMI over LAN
You can connect the IPMI over a LAN connection, too. The prerequisite for this
access type is a host system with IPMI V1.5 and a network adapter with a side-
band connection to the BMC (mostly on board). In the IPMI Settings you have to
enter the IP address of this host system, the user name of a valid IPMI account
and password for this account. You can also access other IPMI systems if you
enter their IP address.
Date And Time
Figure 6-34. Date and Time
This link refers to a page where the internal realtime clock of the B050-000 can be
set up (see Figure 6-34). You have the possibility to adjust the clock manually or to
use a NTP time server. Without a time server your time setting will not be persistent,
so you have to adjust it again after the B050-000 loses power for more than a few
minutes. To avoid this you can use a NTP time server which sets up the internal clock
82